The JETone Dispenser from Titertek will get you up and running quick as a flash. These fully automated, user-friendly microplate dispensing systems are permanently factory calibrated, come with an integrated 60 plate or 180 plate stacker and are completely stand-alone. No PC required! The robust and reliable Titertek Digiflex pipetter, fitted with our unique positive displacement syringes and precision delivery tips, is at the core of each JETone Dispenser. The entire liquid path is made from chemically resistant materials and accuracy and precision are totally independent of reagent viscosity. The JETone dispensers from Titertek are fast, accurate, durable and the most cost effective available. With a variety of syringe packages available, the JETone Dispensers have dispensing ranges of 0.5ul to 2.2ml and can dispense to 96, 384, 1536 and deep well plates. Using manifolds and large volume syringes, the JETone is a real workhorse for large volume, rapid, repetitive fluid addition steps in both standard height and deep well plates.
Overall dimensions
|
Digiflex:
15.50 in (H) x 6.75 in
(W) x 12.25 in (D) - (D) includes 2 inches for cable clearance
39.4 cm (H) x 17.1 cm
(W) x 31.12 cm (D)
JETone Dispenser: - With standard S30
magazines
23.5 in (H) x 18.5 in
(W) x 22 in (D) - (D) includes 2 inches for cable clearance
59.7 cm (H) x 47 cm (W)
x 55.9 cm (D)
JETone Dispenser: - With optional S60
magazines
40.0 in (H) x 18.5 in
(W) x 22 in (D) - (D) includes 2 inches for cable clearance
101.6 cm (H) x 47 cm
(W) x 55.9 cm (D)
|
||||||||
Weight (total)
|
Digiflex:
26.0 lbs. - 11.8 kg
|
JETone Dispenser:
52 lbs. - (23.4 kg)
|
|||||||
Mains power supply
|
100 ― 120 VAC, 50/60 Hz, nominal (operating range 90 ― 130 VAC)
200 ― 240 VAC, 50/60 Hz, nominal (operating range
180 ― 256 VAC)
|
||||||||
Power consumption
|
100 VA Typical
|
||||||||
Fuses
|
Digiflex:
Slow-blow 1.5 amp for
115 V
Slow-blow .75 amp for
230 V
|
JETone Dispenser:
Slow-blow 3 amp for 115
V
Slow-blow 1.5 amp for
230 V
|
|||||||
Operating conditions
(Indoor use)
|
+10°C ― +40°C (tested according to IEC 68-2-1, test Ab, cold, IEC 68-2-2, test Bb, dry heat and IEC 68-2-3,
test Ca, RH 80 %, damp heat, steady state)
|
||||||||
Transportation
conditions
|
-40°C ― +70°C (tested according to IEC 68-2-1, test Ab, cold test and IEC
68-2-2, test Bb, dry
heat), packed in transport packaging
|
||||||||
Storage conditions
|
-25°C ― +50°C, packed in transport packaging
|
||||||||
Interface
|
Serial RS-232C
|
||||||||
|
400 μl
Syringes
|
1 ml
Syringes
|
10 ml
Syringes
|
||||||
0.5 μl – 400 μl
|
2 μl – 395 μl for 96 well plates
|
5 μl – 395 μl for 96 well plates
|
|||||||
2 μl – 100 μl for 384 well plates
|
5 μl – 100 μl for 384 well plates
|
||||||||
5 μl – 2200 μl for deep well plates
|
|||||||||
Resolution
(Increments)
|
0.1 μl
|
1.0 μl
|
1.0 μl
|
||||||
Dispensing accuracy
|
+/- 3% @ 1 μl
|
+/- 3% @ 2 μl
+/- 1% @ 5 μl
|
+/- 1% @ 25 μl
|
||||||
Dispensing precision
|
CV ≤ 5% @ 1 μl
CV ≤ 10% @ 0.5 μl
|
CV ≤ 5% @ 2 μl
CV ≤ 3% @ 5 μl
|
CV ≤ 5% @ 25 μl
CV ≤ 2.5% @ 100 μl
|
||||||
Prime Volume
|
Minimum prime volume is
about 3.5 ml, ~ 95% recoverable and the user can prime to a container.
|
||||||||
| Description | Catalog No. |
| JETone 60 (Base) – JETone without plumbing, 60 plate stacker with 2 S30 magazines | 0906250 |
| JETone 60 4x400 – JETone fitted with 4 x 400ul syringe package, 60 plate stacker with 2 S30 magazines | 0906250A |
|
JETone 60 4x1 – JETone fitted with 4 x 1ml syringe package, 60 plate stacker with 2 S30 magazines |
0906250B |
| JETone 60 2x10 – JETone fitted with 2 x 10ml syringe package, 60 plate stacker with 2 S30 magazines | 0906250C |
| JETone 60 Deep well (Base) – JETone without plumbing, 60 plate DW stacker with 2 S30 magazines | 0906251 |
| JETone SA (Base) – JETone stand-alone without plumbing | 0906252 |
| JETone 180 (Base) – JETone without plumbing, 180 plate stacker with 4 S60 magazines | 0906253 |